Loading...
HomeMy WebLinkAbout2026-05-07 Planning Commission Agenda Packet1.Call to Order / Roll Call 2.Pledge of Allegiance 3.Agenda Approval 4.Open Forum – Public Comment Opportunity 5.Minutes a.April 2, 2026 Minutes 6.New Business a.Vogt Site Plan 7.Reports/Information a.Planning Project Update 8.Commissioner Liaison Calendar a.Commissioner Liaison Calendar 9.Adjournment Corcoran Planning Commission Agenda May 7, 2026 7:00 PM Appoint Vice-Chair *Includes Materials - Materials relating to these agenda items can be found in the Council Chambers Agenda Packet book located by the entrance. The complete Council Agenda Packet is available electronically on the City website at www.corcoranmn.gov. 1 STAFF REPORT Agenda Item: 5.a Council Meeting: May 7, 2026 Prepared By: Seth Gellman. Community Development Administrative Assistant, Topic: April 2, 2026 Minutes Action Required: Approval Council Action Attachments 1. 2026-04-02 Planning Commission Minutes Draft.docx 2 STAFF REPORT Agenda Item: 6.a Council Meeting: May 7, 2026 Prepared By: Dwight Klingbeil, Planner Topic: Vogt Site Plan Action Required: Council Action Recommendation Attachments 1. 2026-05-07 Vogt Site Plan PC Staff Report.pdf 3 Page 1 of 5 STAFF REPORT City Council Meeting: May 7, 2026 Prepared By: Dwight Klingbeil Topic: Vogt Site Plan (PID 36-119-23-32-0011) (City File No. 26-007) Action Required: Recommendation 60-day review deadline: June 2, 2026 1. Application Request Samuel Vogt, the applicant, requests approval of a site plan to allow a 40% reduction in the front yard setback at 6550 County Road 116. Property owners may request a reduction in the required front yard setback through increased landscaping. 2. Context Zoning and Land Use The 2.25-acre property is zoned Urban Reserve (UR) and guided for Existing Residential uses. The property is located within the Metropolitan Urban Service Area (MUSA) and is located within the fourth stage of the City’s 2040 Staging Plan. The property is currently vacant. Surrounding Properties The properties to the north, east, and south are also zoned UR and guided for Existing Residential uses and are currently vacant parcels. The properties to the west are zoned Planned Unit Development (PUD), guided for Low Density Residential uses, and are currently used as single-family homes as part of the Tavera development. Natural Characteristics of the Site The 2040 Natural Resources Communities Quality map identifies a stream along the rear property line, and a wetland in the northeast corner of the lot. The proposed construction area is not located near this wetland area. Figure 1 Site Location 4 Page 2 of 5 3. Analysis Planning staff coordinated review of the request for consistency with the Comprehensive Plan, Zoning Ordinance, City Code requirements, and City policies. The City Engineer’s comments are incorporated into this staff report. The detailed comments are included in the attached Engineering Memo, and the approval conditions require compliance with the Memo. The City’s discretion in approving or denying a Site Plan is limited to whether the proposed request meets the standards outlined in the City Code. If it meets these standards, the City must approve the Site Plan. I. Reduced Setback Flexibility through Landscaping The applicant proposes to construct a detached structure that is setback 60 feet from the front property line, where a 100-foot setback is typically required. Property owners may reduce setback requirements by 40% by installing landscaping beyond the minimum requirements of the Zoning Ordinance. The Zoning Ordinance allows this flexibility, but requires City Council approval of the flexibility: Figure 2 Site Layout 5 Page 3 of 5 K. Building Setback Flexibility through Additional Landscaping. A reduction in the required front setback adjacent to arterial streets may be approved by the City Council if the applicant provides landscaping beyond the minimum requirements or preserves significant landscaping in this area. The required setback may be reduced up to 40 percent if the applicant provides a minimum of one overstory deciduous tree, one overstory coniferous tree, 2 ornamental trees and 10 understory shrubs per 100 feet of the length of the property line where the flexibility is requested, or preserves the equivalent amount of existing trees and shrubs. These materials must be provided in addition to the minimum landscape requirements The intent of this section of the Zoning Ordinance was to acknowledge the City’s desire for a 100-foot setback along major roadways in order to create green corridors through the city, while acknowledging that a similar feeling can be evoked through the use of significant landscaping. The ordinance gives the City Council discretion to consider both new and existing trees. The proposed building location is located in the southeastern corner of the property and is located 60 feet from the front property line, 25 feet from the nearest side property line and ~290 feet from the rear property line. The proposed location complies with the minimum setback requirements for the side and rear property lines (25 feet and 30 feet respectively). The applicant requests that reduced setback flexibility be provided for 95 feet of frontage along County Road 116. To achieve this flexibility, the applicant shall install the following pieces of landscaping: - 1 overstory deciduous tree - 1 overstory coniferous tree - 2 ornamental trees - 10 understory shrubs The proposed site plan includes 1 existing deciduous tree (Eastern Juniper), 1 existing coniferous overstory tree (Red Sunset Maple Tree), 2 new ornamental trees (Flowering Dogwood Trees), and 10 understory shrubs (Danica Arborvitae). The quantity of existing and new plantings satisfies the requirements for the setback flexibility. Section 1060.070 Subd.2.D. of the Zoning Ordinance outlines the minimum plant size requirements for landscaping requirements. The minimum plant size requirements is as follows: 6 Page 4 of 5 The size information provided by the applicant satisfies this requirement. Building Size The applicant proposes the construction of a 1,590 square foot structure in the southeast corner of the property. This structure is intended to serve as the principal dwelling in the near term, with the applicant indicating plans to construct a larger home on the property in the future. Of the total building footprint, approximately 1,225 square feet would be dedicated to living space (e.g., bedroom, kitchen, etc.), which exceeds the minimum residential building size requirement of 1,110 square feet. If a new principal dwelling is constructed in the future, the proposed structure would be reclassified as an accessory structure and would be required to comply with the applicable accessory structure standards of the Zoning Ordinance. For a property of this size (2.25 acres), the maximum cumulative accessory structure footprint permitted is 1,594 square feet. At 1,590 square feet, the structure would comply with this limitation. If the structure were reclassified as an accessory building, it would also be subject to the sidewall height limit requirements of the front yard. Under the current ordinance, accessory structures in the front yard are limited to a sidewall height limit of 10 feet. However, property owners are allowed to exceed this limit through a Conditional Use Permit (CUP). The sidewall height of the proposed structure is 10’1/8”, which is allowed for a principal dwelling. However, the applicant would need to secure the proper approvals if the structure were reclassified as an accessory structure in the future. It’s worth noting that Accessory Dwelling Units (ADUs) in the UR district are limited to a floor area of 960 square feet. If the applicant were to reclassify the structure as an ADU, the floor area of the living space would need to be reduced to 960 square feet or less. Alternatively, if the structure were to be reclassified as an accessory building, the living space would need to be removed or modified such that the structure no longer functions as a dwelling unit. 7 Page 5 of 5 Architectural Standards The proposed structure would be constructed with Pro Rib Steel siding and wainscot. Section 1060.050 Subd. 1.B. does not outwardly list metal as an allowed building material, however, this section does allow for “other materials deemed appropriate and subject to approval by the zoning administrator.” Staff reviewed the proposed materials and found that they were appropriate for the proposed use on the site. The structure would also be constructed with Pro Rib Steel roofing. Section 1060.050 Subd. 1.B.2. allows for metal roof coverings through a Certificate of Compliance, provided the roofing meets the standards of the Minnesota State Building Code, have concealed fasteners, have high quality commercial thickness/weight, and have been treated with a factory applied color coating system against fading or degradation. More information is needed before Staff can issue a Certificate of Compliance for the roofing materials. As a condition of approval, the applicant shall obtain a certificate of compliance for the metal siding and roofing, or revise the plans to a material that is acceptable under the Residential District Standards. The Zoning Ordinance requires eaves (i.e., the underside or soffits on the side) and overhangs (i.e., the edge extending over the front and rear elevations) of at least 12 inches. The applicant is proposing eaves and overhangs that meet this requirement. Grading and Drainage The engineer memo contains a number of conditions related to the grading of the proposed site plan. The applicant shall review the memo and revise the site plan to satisfy the comments made in the attached Engineer Memo from April 23, 2026. 4.Recommendation Staff recommend approval of the draft resolution approving the CUP for a detached garage exceeding the allowed accessory sidewall limit of 10 feet in the side yard. Attachments: 1.Resolution 2026- Approving the Site Plan for reduced flexibility along County Road 116 2.Engineering Memo dated April 23, 2026 3.Certificate of Survey received on March 12, 2026 4. Landscaping Plan received on March 31, 2026 5.Building Plans received on February 17, 2026 Figure 3 Building Elevation 8 City of Corcoran May 28, 2026 County of Hennepin State of Minnesota RESOLUTION NO. 2026- Page 1 of 3 Motion By: Seconded By: A RESOLUTION APPROVING A SITE PLAN FOR A REDUCED SETBACK AT 6550 COUNTY ROAD 116 (PID 36-119-23-32-0011) (CITY FILE 26-007) WHEREAS, Samuel Vogt requests approval of a site plan to allow a reduced setback along a major roadway as allowed in Section 1060.070 Subd. 2.K. of the Corcoran City Code at property legally described as follows: See Attachment A WHEREAS, the Planning Commission reviewed the site plan at a duly called Public Hearing and recommends approval, and; NOW, THEREFORE, BE IT HEREBY RESOLVED BY THE CITY COUNCIL OF THE CITY OF CORCORAN, MINNESOTA, that it should and hereby does approve the request, subject to the following findings and conditions: 1. The site plan is approved, in accordance with the application received by the City on March 12, and additional information received on March 31, 2026. 2. The applicant shall comply with all conditions of the City Engineer’s memo dated April 23, 2026. 3. The site plan is approved with a 60-foot setback from County Road 116 where 100 feet is typically allowed based on the finding that the applicant has provided sufficient landscaping in the area in order to be eligible for the reduction as outlined in Section 1060.070 Subd. 2.K. 4. No other exemptions or variances are granted. 5. A building permit is required prior to construction of the dwelling. 6. The applicant must apply for, and receive, a certificate of compliance for metal roofing and siding, or revise the building materials to satisfy the residential district building materials requirements of Section 1060.050 Subd. 1.B. 7. The structure cannot be used for commercial purposes unless the applicant applies for City approval of a home occupation and such approval is granted. 8. The structure cannot be used as an Accessory Dwelling Unit unless the applicant applies for City approval and such approval is granted. 9. Prior to issuance of a building permit, the applicant/landowner must complete the following: a. A grading plan must be submitted for final approval per the City’s Engineer Memo. The grading plan should incorporate all of the comments identified within the City Engineer’s memo dated April 23, 2026. 9 City of Corcoran May 28, 2026 County of Hennepin State of Minnesota RESOLUTION NO. 2026- Page 2 of 3 b. The approving resolution must be recorded at Hennepin County. c. The applicant/landowner must provide proof of recording to the City. 10. The applicant must maintain a positive escrow balance through the duration of the project. If the escrow balance becomes negative, the applicant must pay any balance due plus a new deposit for anticipated remaining staff time within 30-days of receiving a notice from the City. 11. A final inspection of the project to confirm the building is constructed to plan is required prior to final reconciliation and release of the escrow account with the City. VOTING AYE VOTING NAY McKee, Tom McKee, Tom Friedrich, Michelle Friedrich, Michelle Lanterman, Mark Lanterman, Mark Nichols, Jeremy Nichols, Jeremy Vehrenkamp, Dean Vehrenkamp, Dean Whereupon, said Resolution is hereby declared adopted on this 28th day of May, 2026. ________________________________ Tom McKee - Mayor ATTEST: ____________________________________ City Seal Debra Johnson – City Clerk 10 City of Corcoran May 28, 2026 County of Hennepin State of Minnesota RESOLUTION NO. 2026- Page 3 of 3 ATTACHEMENT A Lot 9, Block 3, Country Seasons Estates 11 To: Kevin Mattson, PE Public Works Director From: Steve Hegland, PE - HAI Dan Boyum, PE Memo Project: 6550 County Road 116 – Lot Survey Review Date: April 26, 2026 We have completed our review of the Lot Survey for 6550 County Road 116 and have the following comments: 1. The property address should be added to the certificate. 2. The certificate of survey should identify elevations for the proposed shed. 3. The grading plan shows the runoff from the county road being routed down and through the driveway. The grading should be adjusted to capture the runoff in a swale and route around the building site. a. If a culvert is necessary to convey runoff, it should be constructed in accordance with the City Standard details and information should be included on the site plan. 4. The grading plan shall show the grading around the house in compliance with the requirements of the building code, including maintaining 5% drainage for the first 10’ from the structure. 5. The driveway will need to be permitted through Hennepin County. The applicant has obtained a temporary driveway permit for a gravel access. The applicant shall be responsible for obtaining a permeant driveway access permit through Hennepin County for the home access. 6. The driveway grades are too steep and should be adjusted. 7. The applicant shall apply for and receive a permit for the septic system from Hennepin County. 8. Show the location of the proposed well on the site plan to ensure applicable setbacks are met. 9. Adjust all proposed site grading to be no steeper than 4:1. 10. The site plan is referencing a wetland delineation report that has not been submitted and finalized with the LGU. The applicant may proceed with either of the following: a. Submit the Kjolhaug Environmental Services Company wetland delineation to the City for review and approval through the WCA process. This would include paying all of the applicable fees and escrows required of a wetland delineation submittal. b. Update the site plan to show the previously approved wetland delineation for this property which was permitted with the Gleason Parkway Project. 11. The site plan shall show the floodplain boundary and identify the adjacent floodplain elevation of 973.42. 12. For large non-urbanized lots, the plans should identify the restoration areas for the entire site including which areas will be maintained and minimally maintained and how vegetation will be established. End of Comments 12 13 60 ' R . O . W . S E T B A C K Proposed Shed (32' x50') 16' Pe r S e c t i o n 1 0 6 0 . 0 7 0 , S u b d . 2 ( K ) Future Proposed House (30' x50') Driveway Septic System Drain Field 20' Septic Tanks 992 991 990989 988 987 986 985 Silt Fence = Understory Shrubs (1) - Plant Spring of 2027 = Over Story Deciduous (1) - Established Already = Over Story Coniferous (2) - Established Already = Ornamental Trees (2) - Plant Spring of 2027 *Plant Size and Type in Table on Application* 14 Architectural Elevations: - Base Elevation: 986 Feet - Sidewall Height: 10’ 1-1/8” (~996 Ft Elevation) - Peak height: 16’ (1002 Ft Elevation) - Roof and Siding: Pro Rib Steel (Midnight Black) - Trim: Pro Rib Steel (Charcoal Black) - Wainscot: Pro Rib Steel (Charcoal Black) 15 16 STAFF REPORT Agenda Item: 7.a Council Meeting: May 7, 2026 Prepared By: Dwight Klingbeil, Planner Topic: Planning Project Update Action Required: Council Action Information Attachments 1. 2026-05-07 Planning Project Update.pdf 17 Page 1 of 2 MEMO Meeting Date: May 7, 2026 To: Planning Commission From: Dwight Klingbeil Re: Planning Project Update Projects/comments in blue italics are new. The following is a status summary of active planning projects: 1. St. Therese Phase 2 Site Plan (PID 24-119-23-32-0004) (City File 25-043). Saint Therese of Corcoran submitted a site plan for phase 2 of their campus, which would consist of 36 additional units at 19800 79th Place. Part of the request included an approval to allow the applicant to utilize the City-owned land on County Road 116 for construction staging. The Planning Commission reviewed this item during the February 5, 2026, meeting. After some discussion, the Planning Commission voted 3:0 to recommend approval of the site plan. The City Council reviewed this item during the February 26, 2026, meeting. The discussion included the applicants satisfying their landscaping requirements off-site on the adjacent parcel along County Road 116, as well as the development of the northern spur of the linear park. The Council voted to approve the Site Plan as presented. 2. Kariniemi Orchards Preliminary Plat (PID 11-119-23-21-0002) (City File 25-044). Nate Kariniemi submitted a preliminary plat application for a 12-lot subdivision at 20400 County Road 30. The Planning Commission reviewed this item during the April 2, 2026, Planning Commission meeting. After some discussion, the Planning Commission motioned to recommend approval of the preliminary plat. The item was intended to be scheduled for the April 23, 2026, City Council meeting. However, the applicant requested that the item be scheduled to a later date to allow for additional review of the amended trail alignment. This item is scheduled for the May 28, 2026, City Council meeting. 3. Springs at Corcoran Preliminary Plat, Preliminary PUD, Rezoning (PID 12-119- 23-13-0007) (City File 26-001). 18 Page 2 of 2 Continental 928 Fund, LLC. Request approval of a preliminary plat, preliminary Planned Unit Development (PUD), and rezoning to allow the construction of 294 market-rate rental units at 19330 County Road 30. The site is currently zoned General Mixed-Use. The applicant is requests the site be rezoned to Planned Unit Development (PUD), with an underlying zoning district of GMU. This item is being reviewed for completeness and is not currently scheduled for any upcoming meetings. 4. Lindberg ADU (PID 21-119-23-23-0001) (City File 26-002). Heidi Lindberg requests approval of a Conditional Use Permit to allow the construction of an. accessory dwelling unit that exceeds 960 sq. ft. and is less than 1,200 sq. ft. at 8301 Strehler Road. The Council approved this item during the April 23, 2026, City Council meeting. 5. Ulfers Garage CUP (PID 04-119-23-34-0001) (City File 26-003). John Ulfers requests approval of a Conditional Use Permit to allow the construction of an accessory building with a sidewall height of 16 ft. in the side yard of 22085 Oakdale Drive. To further understand the Home Occupation operating on the property, the Council voted to table this item to a future meeting in June. 6. Wiseman Garage CUP (PID 24-119-23-31-0008) (City File 26-004). Allan Dorney Construction MN LLC requests approval of a Conditional Use Permit to allow the construction of an accessory building with a sidewall height of 12 ft. in the front yard of 7938 Maple Hill Road. This item was approved by the Council during the April 23, 2026, City Council meeting. 7. Brockton Business Park Phase 2Wiseman Garage CUP (PID 24-119-23-31-0008) (City File 26-006). Hemple Development requests approval of phase 2 of their Light Industrial Development, “Brockton Business Park”. The second phase would construct the eastern building, which consists of 252,120 square feet of office/warehouse space. This item was approved by the Council during the April 23, 2026, City Council meeting. 8. Vogt Site Plan (PID 36-119-23-32-0011) (City File 26-007). Samuel Vogt requests approval of a site plan to allow for a reduced front setback from a County Road, through the installation of additional landscaping, at 6550 County Road 116. This application is scheduled for the May 7, 2026, Planning Commission meeting. 9. Weinand Woods 2nd Addition (PID 36-119-23-32-0011) (City File 26-009). Kevin and Mary Weinand requests approval of a preliminary plat to adjust the shared boundary line between the property as 22939 County Road 30, and Outlot B of Weinand Woods Addition. This application is under review for completeness and is not currently scheduled for any upcoming meetings. 19 STAFF REPORT Agenda Item: 8.a Council Meeting: May 7, 2026 Prepared By: Dwight Klingbeil, Planner Topic: Commissioner Liaison Calendar Action Required: Council Action Attachments 1. Commissioner Liaison Calendar.pdf 20 Suggested City Council Meetings: 5/14/2026 5/28/2026 6/11/2026 6/25/2026 7/9/2026 7/23/2026 Brummond Hargreaves Kozicky Scherber Zachman Brummond Commissioner Liaison Calendar 21